Examples
Examples
Try the starting example
- Finished outer box [length,width,height] mm
- 120,80,60
- Measured linear shrinkage (%)
- 12
- Green slab thickness (mm)
- 6
- Green joining allowance per panel edge (mm)
- 2
- Green cut panels [label,count,width mm,height mm]
- [["Base",1,140.363636364,94.9090909091],["Long wall",2,140.363636364,66.1818181818],["Short wall",2,82.9090909091,66.1818181818]]
- Total green cutting area (mm²)
- 42,874.975207
Try another scenario
- Finished outer box [length,width,height] mm
- [140, 100, 70]
- Measured linear shrinkage (%)
- 12
- Green slab thickness (mm)
- 6
- Green joining allowance per panel edge (mm)
- 2
- Green cut panels [label,count,width mm,height mm]
- [["Base",1,163.090909091,117.636363636],["Long wall",2,163.090909091,77.5454545455],["Short wall",2,105.636363636,77.5454545455]]
- Total green cutting area (mm²)
- 60,862.578512
Calculation method
Calculation method
Green cut panels [label,count,width mm,height mm]
Bottom under walls: base uses outer L×W; long walls L×(H−base thickness); short walls (W−2wall thickness)×(H−base thickness); add2×join allowance to each cutting dimension.
Total green cutting area (mm²)
Sum all five panel cutting rectangles; open-top box.
Symbols and units
- a
- Finished outer box [length,width,height] mm
- b
- Measured linear shrinkage (%)
- c
- Green slab thickness (mm)
- d
- Green joining allowance per panel edge (mm)
Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.
Assumptions & limits
Assumptions & limits
- Finished shape, shrinkage, slab thickness, joining allowance. Returns Panel cutting templates. All coefficients and observations are user supplied; results describe only the stated mathematical model. Quantities are deterministic calculations from supplied observations and assumptions; no external data is fetched. Supported limits: Finite inputs only; numeric fields bounded as labelled. Lists and JSON records are limited to 256 entries unless a stricter tool bound is stated. No automatic design approval, legal conclusion, treatment recommendation or safety certification. Finished outer box [length,width,height] mm: minimum 1e-12, maximum 1000000000000.0. Measured linear shrinkage (%): minimum 0, maximum 99. Green slab thickness (mm): minimum 1e-12, maximum 1000000000000.0. Green joining allowance per panel edge (mm): minimum 0, maximum 1000000000000.0.
Are these inputs private?
These calculations run in your browser. A shared link contains the values you choose to share. Only questions submitted to the separate AI finder are sent to OpenAI.