Examples
Examples
Try the starting example
- Wet reference length (mm)
- 100
- Dry length (mm)
- 95
- Fired length (mm)
- 88
- Drying shrinkage (%)
- 5
- Firing shrinkage relative to dry (%)
- 7.368421
- Total wet-to-fired shrinkage (%)
- 12
Try another scenario
- Wet reference length (mm)
- 100
- Dry length (mm)
- 95
- Fired length (mm)
- 85
- Drying shrinkage (%)
- 5
- Firing shrinkage relative to dry (%)
- 10.526316
- Total wet-to-fired shrinkage (%)
- 15
Calculation method
Calculation method
Drying shrinkage (%)
100(wet−dry)/wet.
Firing shrinkage relative to dry (%)
100(dry−fired)/dry.
Total wet-to-fired shrinkage (%)
100(wet−fired)/wet; stage percentages do not add directly.
Symbols and units
- a
- Wet reference length (mm)
- b
- Dry length (mm)
- c
- Fired length (mm)
Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.
Assumptions & limits
Assumptions & limits
- Wet, dry and fired measurements. Returns Stage and total shrinkage. All coefficients and observations are user supplied; results describe only the stated mathematical model. Quantities are deterministic calculations from supplied observations and assumptions; no external data is fetched. Supported limits: Finite inputs only; numeric fields bounded as labelled. Lists and JSON records are limited to 256 entries unless a stricter tool bound is stated. No automatic design approval, legal conclusion, treatment recommendation or safety certification. Wet reference length (mm): minimum 1e-12, maximum 1000000000000.0. Dry length (mm): minimum 1e-12, maximum 1000000000000.0. Fired length (mm): minimum 1e-12, maximum 1000000000000.0.
Are these inputs private?
These calculations run in your browser. A shared link contains the values you choose to share. Only questions submitted to the separate AI finder are sent to OpenAI.