Coolant blend replacement arithmetic calculator

Calculate modeled concentration after each complete drain/refill and final modeled concentration with your own figures.

Your numbers

Use the units shown. Results update as you change valid inputs.

Use modeled concentration after each complete drain/refill and final modeled concentration to compare changes to your inputs. The method and limits below explain the scope.

Examples

Examples

Try the starting example

Fixed ideally mixed system volume (L)
10
Initial concentration on supplied comparable percentage basis
40
Drain/refill stages: ID, drained L, replacement concentration %
S1,2,0 S2,2,100
Modeled concentration after each complete drain/refill (%)
S1: 32; S2: 45.6
Final modeled concentration (%)
45.6
Total replacement volume added (L)
4
Final modeled solute-equivalent volume (L)
4.56

Try another scenario

Fixed ideally mixed system volume (L)
10
Initial concentration on supplied comparable percentage basis
40
Drain/refill stages: ID, drained L, replacement concentration %
S1,2,0 S2,2,50
Modeled concentration after each complete drain/refill (%)
S1: 32; S2: 35.6
Final modeled concentration (%)
35.6
Total replacement volume added (L)
4
Final modeled solute-equivalent volume (L)
3.56
Calculation method

Calculation method

Modeled concentration after each complete drain/refill (%)

New concentration=old×(1−drained/system)+replacement×drained/system, fully mixing before next stage.

Final modeled concentration (%)

Last stage concentration without clipping or choosing a target.

Total replacement volume added (L)

Sum supplied drained/replaced volumes.

Final modeled solute-equivalent volume (L)

Fixed system volume×final concentration/100, under additive comparable-volume assumptions.

Symbols and units
a
Fixed ideally mixed system volume (L)
b
Initial concentration on supplied comparable percentage basis
c
Drain/refill stages: ID, drained L, replacement concentration %

Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.

Assumptions & limits

Assumptions & limits

  • An ideal nonreacting constant-volume drain/refill concentration model. It does not identify coolant chemistry, compatibility, freeze protection, actual mixing behavior or an acceptable vehicle specification.
Are these inputs private?

These calculations run in your browser. A shared link contains the values you choose to share. Only questions submitted to the separate AI finder are sent to OpenAI.