Depot coincident charging peak calculator

Calculate site trace [start,end,total grid kW] and coincident site peak with your own figures.

Your numbers

Use the units shown. Results update as you change valid inputs.

Use site trace [start,end,total grid kW] and coincident site peak to compare changes to your inputs. The method and limits below explain the scope.

Examples

Examples

Try the starting example

Piecewise-constant charger power JSON [charger ID,start minute,end minute,grid kW]
[["C1",0,60,10],["C1",60,120,5],["C2",30,90,10]]
Constant site base load (kW)
5
Site trace [start,end,total grid kW]
[[0,30,15],[30,60,25],[60,90,20],[90,120,10]]
Coincident site peak (kW)
25
Peak intervals [start,end] (minutes)
[[30,60]]
Site energy over trace span (kWh)
35

Try another scenario

Piecewise-constant charger power JSON [charger ID,start minute,end minute,grid kW]
[["C1",0,60,10],["C1",60,120,5],["C2",60,120,10]]
Constant site base load (kW)
5
Site trace [start,end,total grid kW]
[[0,60,15],[60,120,20]]
Coincident site peak (kW)
20
Peak intervals [start,end] (minutes)
[[60,120]]
Site energy over trace span (kWh)
35
Calculation method

Calculation method

Site trace [start,end,total grid kW]

Sweep all supplied segment boundaries; sum active piecewise powers plus constant base load over every half-open interval.

Coincident site peak (kW)

Maximum site trace power.

Peak intervals [start,end] (minutes)

Return all swept intervals tied for peak.

Site energy over trace span (kWh)

Integrate every charger segment plus baseLoad*(lastBoundary-firstBoundary)/60.

Symbols and units
a
Piecewise-constant charger power JSON [charger ID,start minute,end minute,grid kW]
b
Constant site base load (kW)

Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.

Assumptions & limits

Assumptions & limits

  • Exact piecewise-constant grid-power trace over supplied span. No diversity factor assumed. Peak is instantaneous segment power, not tariff demand averaging, transformer sizing or battery-side power. Supported limits: 1..1000 positive-duration integer-minute segments; same-charger segments may touch but not overlap; power/base>=0; at least one segment.