3D printing and digital fabrication

Extrusion flow calibration calculator

Multiply the current flow factor by target width / measured width. Use a suitable single-wall test and repeat measurements. Adaptive line widths, mechanical errors and imprecise measurements can invalidate this estimate.

Your numbers

Use the units shown. Results update as you change valid inputs.

YOUR RESULT

Multiply the current flow factor by target width / measured width. Use a suitable single-wall test and repeat measurements. Adaptive line widths, mechanical errors and imprecise measurements can invalidate this estimate.

THE NUMBERS, EXPLAINED

How to use this calculator.

Multiply the current flow factor by target width / measured width. Use a suitable single-wall test and repeat measurements. Adaptive line widths, mechanical errors and imprecise measurements can invalidate this estimate.

Start with your inputs

Enter target wall width (mm), measured wall width (mm), current flow multiplier. Keep amounts in the units shown on each field. The example is a starting point, not a recommended value.

InputExample value
Target wall width (mm)0.45
Measured wall width (mm)0.5
Current flow multiplier1

A worked example

With the example inputs above, proposed flow multiplier is 0.9. Change the inputs to explore your own scenario.

Putting the example numbers into the formula

Proposed flow multiplier
(1) × (0.45) ÷ (0.5) = 0.9

Correction (%)
((0.45) ÷ (0.5)-1) × 100 = -10

All results for the example inputs above
ResultExample answer
Proposed flow multiplier0.9
Correction (%)-10

How this is calculated

Proposed flow multiplier

c × a ÷ b

Correction (%)

(a ÷ b-1) × 100

Symbols and units
a
Target wall width (mm)
b
Measured wall width (mm)
c
Current flow multiplier

Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.

Assumptions and limits

Multiply the current flow factor by target width / measured width. Use a suitable single-wall test and repeat measurements. Adaptive line widths, mechanical errors and imprecise measurements can invalidate this estimate.

Calculations use the values you enter. Blank or invalid inputs show an error instead of silently substituting zero. Results are displayed to useful precision; calculations retain the underlying numeric precision.

Questions about this tool

What does the result tell me?

Proposed flow multiplier; Correction (%). The result applies to the method and inputs described above. Check the units and assumptions before using it in a decision.

Why might another calculator differ?

Differences in units, rounding, timing or model definitions can produce different answers. Compare the input definitions and the method, rather than only the final number. For this tool: Multiply the current flow factor by target width / measured width. Use a suitable single-wall test and repeat measurements. Adaptive line widths, mechanical errors and imprecise measurements can invalidate this estimate.

Are my inputs stored or sent to AI?

Calculations on this page happen in your browser. The separate AI question finder sends its submitted conversation to OpenAI; these calculator fields are not sent. Favourites and recent tool names are stored locally. A shared link contains the inputs you choose to include.

Further reading

Prusa: extrusion multiplier calibration ↗

Background reading; this does not imply endorsement or independent review of SumFizz.

Review status

Software example and browser checks are recorded in our quality report. No external expert review is claimed. Created with coding assistance; calculations run as ordinary browser code.

Read the quality report →