Energy and household resources

Insulation heat-loss scenario calculator

Steady-state conduction through one surface only. Ignores thermal bridges, infiltration and changing weather.

Your numbers

Use the units shown. Results update as you change valid inputs.

YOUR RESULT

Steady-state conduction through one surface only. Ignores thermal bridges, infiltration and changing weather.

THE NUMBERS, EXPLAINED

How to use this calculator.

Steady-state conduction through one surface only. Ignores thermal bridges, infiltration and changing weather.

Start with your inputs

Enter surface area (m²), old u-value (w/m²k), new u-value (w/m²k), temperature difference (k), duration (hours). Keep amounts in the units shown on each field. The example is a starting point, not a recommended value.

InputExample value
Surface area (m²)100
Old U-value (W/m²K)2
New U-value (W/m²K)0.5
Temperature difference (K)20
Duration (hours)1000

A worked example

With the example inputs above, avoided heat loss (kwh) is 3,000. Change the inputs to explore your own scenario.

Putting the example numbers into the formula

Avoided heat loss (kWh)
(100) × ((2)-(0.5)) × (20) × (1000) ÷ 1000 = 3,000

All results for the example inputs above
ResultExample answer
Avoided heat loss (kWh)3,000

How this is calculated

Avoided heat loss (kWh)

a × (b-c) × d × e ÷ 1000

Symbols and units
a
Surface area (m²)
b
Old U-value (W/m²K)
c
New U-value (W/m²K)
d
Temperature difference (K)
e
Duration (hours)

Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.

Assumptions and limits

Steady-state conduction through one surface only. Ignores thermal bridges, infiltration and changing weather.

Calculations use the values you enter. Blank or invalid inputs show an error instead of silently substituting zero. Results are displayed to useful precision; calculations retain the underlying numeric precision.

Questions about this tool

What does the result tell me?

Avoided heat loss (kWh). The result applies to the method and inputs described above. Check the units and assumptions before using it in a decision.

Why might another calculator differ?

Differences in units, rounding, timing or model definitions can produce different answers. Compare the input definitions and the method, rather than only the final number. For this tool: Steady-state conduction through one surface only. Ignores thermal bridges, infiltration and changing weather.

Are my inputs stored or sent to AI?

Calculations on this page happen in your browser. The separate AI question finder sends its submitted conversation to OpenAI; these calculator fields are not sent. Favourites and recent tool names are stored locally. A shared link contains the inputs you choose to include.

Review status

Software example and browser checks are recorded in our quality report. No external expert review is claimed. Created with coding assistance; calculations run as ordinary browser code.

Read the quality report →