Motorcycle valve shim worksheet calculator

Calculate candidates whose entire predicted interval lies in target, by valve with your own figures.

Your numbers

Use the units shown. Results update as you change valid inputs.

Use candidates whose entire predicted interval lies in target, by valve to compare changes to your inputs. The method and limits below explain the scope.

Examples

Examples

Try the starting example

Direct-shim observations: valve ID, measured clearance mm, installed shim mm
V1,0.15,2.5 V2,0.25,2.5
Supplied compatible candidate shim thicknesses mm, comma-separated
2.4,2.45,2.5,2.55
Supplied target clearance minimum (mm)
0.2
Supplied target clearance maximum (mm)
0.3
Symmetric clearance measurement uncertainty (mm)
0.01
Candidates whose entire predicted interval lies in target, by valve
V1: 2.4; V2: 2.5
Candidates whose nominal predicted clearance lies in target
V1: 2.4|2.45; V2: 2.45|2.5|2.55
Current nominal measured clearance inside supplied target
V1: No; V2: Yes
Continuous candidate-thickness interval satisfying uncertainty bounds (mm)
V1: 2.36, 2.44; V2: 2.46, 2.54

Try another scenario

Direct-shim observations: valve ID, measured clearance mm, installed shim mm
V1,0.15,2.5 V2,0.25,2.5
Supplied compatible candidate shim thicknesses mm, comma-separated
2.4,2.45,2.5,2.55
Supplied target clearance minimum (mm)
0.2
Supplied target clearance maximum (mm)
0.3
Symmetric clearance measurement uncertainty (mm)
0
Candidates whose entire predicted interval lies in target, by valve
V1: 2.4|2.45; V2: 2.45|2.5|2.55
Candidates whose nominal predicted clearance lies in target
V1: 2.4|2.45; V2: 2.45|2.5|2.55
Current nominal measured clearance inside supplied target
V1: No; V2: Yes
Continuous candidate-thickness interval satisfying uncertainty bounds (mm)
V1: 2.35, 2.45; V2: 2.45, 2.55
Calculation method

Calculation method

Candidates whose entire predicted interval lies in target, by valve

Use predicted clearance=measured+installed shim−candidate, and require predicted±uncertainty inside supplied target.

Candidates whose nominal predicted clearance lies in target

Apply the same direct-shim model at nominal measured clearance only.

Current nominal measured clearance inside supplied target

Compare nominal current measurement to supplied inclusive target interval.

Continuous candidate-thickness interval satisfying uncertainty bounds (mm)

[measured+uncertainty+installed−target max, measured−uncertainty+installed−target min]; report Empty if reversed.

Symbols and units
a
Direct-shim observations: valve ID, measured clearance mm, installed shim mm
b
Supplied compatible candidate shim thicknesses mm, comma-separated
c
Supplied target clearance minimum (mm)
d
Supplied target clearance maximum (mm)
e
Symmetric clearance measurement uncertainty (mm)

Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.

Assumptions & limits

Assumptions & limits

  • Arithmetic for an explicitly supplied direct shim-to-clearance minus-one relationship, not a universal valve-train model or installation instruction. Shim compatibility, target, uncertainty, mechanism and final physical verification are external; no part is selected or ordered.
Are these inputs private?

These calculations run in your browser. A shared link contains the values you choose to share. Only questions submitted to the separate AI finder are sent to OpenAI.

Further reading

OpenStax: ratios, unit rates and supplied measurement arithmetic ↗

Background reading; this does not imply endorsement or independent review of SumFizz.

Share this page
Share this calculator

Leave unchecked to share the page without your entered values.