Process conductivity calibration calculator

Calculate piecewise-linear interpolated concentrations and linear calibration residuals with your own figures.

Your numbers

Use the units shown. Results update as you change valid inputs.

Use piecewise-linear interpolated concentrations and linear calibration residuals to compare changes to your inputs. The method and limits below explain the scope.

Examples

Examples

Try the starting example

Reference concentrations
0,1,2,4
Reference conductivities (same temperature)
0,2,4,8
Sample conductivity readings
1,3,6
Piecewise-linear interpolated concentrations
[0.5,1.5,3]
Linear calibration residuals
[0,0,0,0]

Try another scenario

Reference concentrations
[0, 1, 2, 4]
Reference conductivities (same temperature)
[0, 2, 4, 8]
Sample conductivity readings
[2, 4, 7]
Piecewise-linear interpolated concentrations
[1,2,3.5]
Linear calibration residuals
[0,0,0,0]
Calculation method

Calculation method

Piecewise-linear interpolated concentrations

Invert strictly increasing reference conductivity table; no extrapolation.

Linear calibration residuals

Observed reference conductivity minus global OLS conductivity prediction; assess model departure.

Symbols and units
a
Reference concentrations
b
Reference conductivities (same temperature)
c
Sample conductivity readings

Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.

Assumptions & limits

Assumptions & limits

  • Reference concentrations-conductivities, sample readings. Returns Interpolated concentration and residuals. All coefficients and observations are user supplied; results describe only the stated mathematical model. Quantities are deterministic calculations from supplied observations and assumptions; no external data is fetched. Supported limits: Finite inputs only; numeric fields bounded as labelled. Lists and JSON records are limited to 256 entries unless a stricter tool bound is stated. No automatic design approval, legal conclusion, treatment recommendation or safety certification. Reference concentrations: minimum 0, maximum 1000000000000.0. Reference conductivities (same temperature): minimum 0, maximum 1000000000000.0. Sample conductivity readings: minimum 0, maximum 1000000000000.0.
Are these inputs private?

These calculations run in your browser. A shared link contains the values you choose to share. Only questions submitted to the separate AI finder are sent to OpenAI.

Further reading

Method reference ↗

Background reading; this does not imply endorsement or independent review of SumFizz.