Examples
Examples
Try the starting example
- Frequency (Hz)
- 50
- Capacitance (µF)
- 100
- Inductance (mH)
- 100
- Capacitive reactance (Ω)
- 31.830989
- Inductive reactance (Ω)
- 31.415927
Try another scenario
- Frequency (Hz)
- 55.00000000000001
- Capacitance (µF)
- 100
- Inductance (mH)
- 100
- Capacitive reactance (Ω)
- 28.937262
- Inductive reactance (Ω)
- 34.557519
Calculation method
Calculation method
Capacitive reactance (Ω)
If b = 0, report Open circuit. Otherwise 1/(2 × π × a × b/10^6).
Inductive reactance (Ω)
2 × π × a × c/1000.
Symbols and units
- a
- Frequency (Hz)
- b
- Capacitance (µF)
- c
- Inductance (mH)
Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.
Assumptions & limits
Assumptions & limits
- Reactance magnitudes for ideal components at a single sinusoidal frequency.
Are these inputs private?
These calculations run in your browser. A shared link contains the values you choose to share. Only questions submitted to the separate AI finder are sent to OpenAI.
Further reading
Background reading; this does not imply endorsement or independent review of SumFizz.