Examples
Examples
Try the starting example
- Constant tank horizontal area (m²)
- 2
- Outlet area (m²)
- 0.001
- Initial head (m)
- 2
- Final head (m)
- 0.1
- Discharge coefficient
- 0.62
- Ideal drain time (seconds)
- 1,599.52005
- Discharged volume (m³)
- 3.8
Try another scenario
- Constant tank horizontal area (m²)
- 2.2
- Outlet area (m²)
- 0.001
- Initial head (m)
- 2
- Final head (m)
- 0.1
- Discharge coefficient
- 0.62
- Ideal drain time (seconds)
- 1,759.472055
- Discharged volume (m³)
- 4.18
Calculation method
Calculation method
Ideal drain time (seconds)
Integrated Torricelli: t=2At/(Cd Ao sqrt(2g)) (sqrt(h0)-sqrt(h1)).
Discharged volume (m³)
Integrated Torricelli: t=2At/(Cd Ao sqrt(2g)) (sqrt(h0)-sqrt(h1)).
Symbols and units
- a
- Constant tank horizontal area (m²)
- b
- Outlet area (m²)
- c
- Initial head (m)
- d
- Final head (m)
- e
- Discharge coefficient
Use the units shown. A list keeps the order in which you enter its values. The symbol ^ means “raised to the power of”.
Assumptions & limits
Assumptions & limits
- Constant-area vented tank, small outlet, no varying coefficient or connected pipe model. Supported limits: All required fields must be finite values of the exact declared type and within displayed bounds. Lists contain1–1000 finite numbers. JSON tables are numeric rectangular rows, at most100 rows and30 columns; individual tools have stricter shape/domain constraints. Constant-area vented tank, small outlet, no varying coefficient or connected pipe model.
Are these inputs private?